image

The Falcon 8500 is built for facilities where power interruption isn't just inconvenient, it's operationally unacceptable. As a robust online UPS, it provides continuous, zero transfer time power conditioning rather than switching over only when a problem occurs, making it well suited to manufacturing plants and large server rooms that depend on uninterrupted power around the clock. For businesses running critical network environments, the Falcon 8500 is engineered specifically for that level of demand.

Unlike standby or line-interactive designs, an online UPS like the Falcon 8500 continuously runs connected equipment off its inverter, with the incoming utility supply used to keep the battery charged rather than powering the load directly. This means there's no switchover delay when utility power fails, so output remains stable and uninterrupted, which matters significantly in environments where even a momentary gap in power can cause equipment faults or data loss.

This topology is precisely why the Falcon 8500 suits manufacturing plants so well. Production line equipment, control systems, and automated machinery are all sensitive to power irregularities, and a manufacturing plant UPS built on online architecture protects against the voltage sags, surges, and brief interruptions that standard grid power inevitably introduces over time.

The same reliability makes the Falcon 8500 equally effective as a server room UPS. Large server rooms depend on continuous power to avoid downtime, data corruption, or hardware damage, and critical network environments in particular require the kind of consistent, conditioned output that only genuine online UPS technology reliably delivers. For IT infrastructure running mission-critical applications, this level of protection is often non-negotiable rather than optional.

Flexibility comes from how the Falcon 8500 fits within United Tractor's broader three phase UPS range, which includes the Finch PG, Falcon X5, Falcon X7, UPS 7000HXi, and Falcon 7000M for facilities with different capacity or feature requirements. For businesses researching a comprehensive uninterrupted power supply Sri Lanka strategy for manufacturing or data centre environments specifically, the Falcon 8500's online UPS design makes it a strong fit wherever continuous, zero-gap power protection is the priority.

Technical information

  • Model: FALCON 8500 (Fuji Electric Falcon UPS range)

  • Topology: Online UPS, Double Conversion, Transformer-based

  • Capacity: 30 kVA – 300 kVA

  • Input/Output configuration: 3-phase input and 3-phase output

  • Response time: 5 milliseconds (range-wide Falcon/Finch spec)

  • Operating environment: Functions even in a non-air-conditioned environment

  • Standards: Designed and manufactured to global IEC standards

  • Positioning in range: Transformer-based double-conversion topology versus the transformer-less FALCON 7000 line, with overlapping kVA range around 40-300kVA