Product Description

Providing reliable energy solutions ,our C7.1 diesel generator sets are made to meet your standby and prime three phase applications.

All standby C7.1 generator sets are supplied with 4 years extended service coverage as standard. We’ve designed each to ISO 8528-5 transient response requirements. C7.1 generator sets are available with a choice of emissions levels from non regulated up to EU Stage IIIA emissions compliant. We offer easy-to-use Cat control panels, EMCP 4.1 or EMCP 4.2 options. Browse a broad range of accessories including galvanised sound attenuated enclosures and integral fuel tanks. Our C7.1 generator sets are made for demands, so you can make yours.


REQUEST QUOTE

DOWNLOAD MANUAL

  • SPECIFICATIONS
  • BENEFITS AND FEATURES
  • EQUIPMENT

SPECIFICATIONS

Rating 135kVA, 150kVA, 180kVA,200kVA,
Voltage 400 /230 V
Frequency 50 Hz
Speed 1500 rpm

BENEFITS AND FEATURES

Cat™ Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

Generator

  • Matched to the performance and output characteristics of Cat engines
  • Industry leading mechanical and electrical design
  • Industry leading motor starting capabilities
  • IP 23 Protection

Cat EMCP Control Panel

The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. The EMCP 4 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP 4 systems can be further customized to meet your needs through programming and expansion modules. The EMCP4.1 is fitted as standard.

Design Criteria

  • The generator set is designed to meet ISO8528-5 transient response and NFPA 110.
  • Cooling system designed to operate in 50˚C / 122˚F ambient temperatures with an air flow restriction of 0.5 in. water.

CE Certification

CE Certification available

World Wide Product Support

Cat dealers provide extensive post-sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S•O•S℠ program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products

General

  • Single wall 8 hour wide fuel tank
  • Circuit breaker, IEC, 3 pole
  • Industrial Silencer (10dBA)

 

EQUIPMENT

C7.1 (50 Hz) Standard Equipment

Air Inlet System

  • Air Cleaner; light duty with disposable element

 

Control Panels

  • EMCP4.1 control panel

 

Cooling System

  • Radiator and cooling fan with guards
  • Coolant drain line with valves
  • Fan drive, battery charging alternator drive
  • Caterpillar extended life coolant

 

Exhaust System

  • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use; shipped loose

 

Fuel System

  • Standard open set fuel tank / base supplied
  • Base, formed steel with single wall integral 8-hour fuel tank

 

Generators and Generator Attachments

  • 12 leads
  • IP23 protection
  • Voltage regulator (single phase sensing)
  • Tower panel, IP22, bottom cable entry
  • Segregated low voltage (AC/DC) wiring panel
  • Circuit breaker, IEC, 3 pole, mounted in tower panel

 

Governing System

  • Mechanical and electrical governing system – model dependent

 

Lube System

  • Lubricating oil
  • Oil drain line with valve

 

Mounting System

  • Captive linear vibration isolators between base and engine-generator
  • Includes lifting provision and drag points
  • Termination points for coolant and lube oil drain lines

 

Starting / Charging System

  • 24V battery with rack and cables

 

General

  • Engine and alternator pre-paint, Caterpillar Yellow

 

C7.1 (50 Hz) Optional Equipment

Alternator System

  • Alternator removal
  • R2273L4 SE aux alt 07
  • R2453L4 SE aux alt 08
  • R2473L4 SE aux alt 10

 

Circuit Breakers

  • 4 Pole Circuit Breaker to 250A
  • 4 Pole Circuit Breaker to 400A
  • 4 Pole Circuit Breaker to 630A

 

Control Panel Options

  • Volt free contacts
  • Speed adjust contacts
  • Speed adjust potentiometer
  • Panel mounted audible alarm
  • Earth fault (2 wire only)
  • Earth leakage (2 wire only)
  • Overload shutdown via breaker
  • Battery charger
  • Emergency stop with key
  • Control panel heater

 

Control System

  • EMCP 4.2
  • Static battery charger
  • Control panel heater
  • Volt free contacts for common alarm
  • Volt free contacts for generator set running

 

Cooling System

  • Coolant heater
  • Low coolant temperature
  • Low coolant level shutdown

 

Enclosures

  • Sound attenuated level 2 enclosure
  • Sound attenuated level 1 enclosure
  • Rental options (CAE only) – Single point lift
  • Rental options (CAE only) – Rental pack
  • Rental options (CAE only) – CEE form sockets for enclosure
  • Rental options (CAE only) – Socket blanking plate

 

European Certifications

  • Upgrade to STD set for CE

 

Fuel Systems

  • Open set narrow tankbase
  • Compact skidbase for open sets
  • Skidbase for CALG enclosure sets
  • DEFRA bunded fuel tank
  • Low fuel level shutdown
  • Low fuel level alarm
  • High fuel level alarm

 

Global Certifications

  • Certification for CIS

 

Mounting Options

  • Electronic governor
  • Battery removal
  • Industrial silencer removal
  • Residential silencer
  • Silencer installation kit

 

Power Termination

  • Circuit breaker, IEC, 4 pole

 

Special Packing / Inspections for Shipment

  • PGS test report @ 1.0 PF
  • PGS test report @ 0.8 PF

 

Accessories / Miscellaneous

  • Stone guards / rad trans flange
  • Packing case – compact set
  • Packing case – canopied set

 


Selection of right Construction Equipment for your Project