Producing reliable power from 455 kVA to 600 kVA at 50 Hz, our C18 diesel generator sets are made to meet your standby and prime applications.

Each is designed to ISO 8528-5 transient response requirements and built accept 100 percent rated load in one step. Our C18 generator sets range from low fuel consumption systems to EPA Stationary Emergency (Tier 2) certified. Seismic certification is also available for select models, so you can deliver power despite disturbances. Our integrated control system, including ATS and switchgear ensure a consistent power supply and connection to your fleet through on-site and remote monitoring options. We offer a wide range of EMCP 4 control panel options, with a simple screen display, consolidating all your management and diagnostics tools. The EMCP 4.4 controller provides on package paralleling capability, allowing you to use multiple generator sets to power your facility, providing added capacity and redundancy. We’ve made our generator sets adaptable to your demands with a broad range of accessories and bolt-on system expansion attachments. Find flexible packaging to fit your spatial restrictions and environmental conditions. Even choose UL 2200 and CSA certified package options for added safety.


REQUEST QUOTE

DOWNLOAD MANUAL

  • SPECIFICATIONS
  • BENEFITS AND FEATURES
  • EQUIPMENT

SPECIFICATIONS

Rating 550kVA,600kVA,650kVA
Voltage 400 /230 V
Frequency 50 Hz
Speed 1500 rpm

BENEFITS AND FEATURES

Cat™ Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

Generator

  • Matched to the performance and output characteristics of Cat engines
  • Industry leading mechanical and electrical design
  • Industry leading motor starting capabilities
  • High Efficiency

Cat EMCP Control Panel

The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. EMCP4 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP4 systems can be further customized to meet your needs through programming and expansion modules.

Seismic Certification

  • Seismic Certification available.
  • Anchoring details are site specific, and are dependent on many factors such as generator set size, weight, and concrete strength.
  • IBC Certification requires that the anchoring system used is reviewed and approved by a Professional Engineer
  • Seismic Certification per Applicable Building Codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007, CBC 2010
  • Pre-approved by OSHPD and carries an OSP-0321-10 for use in healthcare projects in California

Design Criteria

The generator set accepts 100% rated load in one step per NFPA 110 and meets ISO 8528-5 transient response.

UL 2200 / CSA – Optional

  • UL 2200 listed packages
  • CSA Certified
  • Certain restrictions may apply.
  • Consult with your Cat® Dealer.

Single-Source Supplier

Fully prototype tested with certified torsional vibration analysis available

World Wide Product Support

Cat dealers provide extensive post-sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S•O•S℠ program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products

 

EQUIPMENT

C18 (50 Hz) Standard Equipment

Air Inlet

  • Air Cleaner

 

Cooling

  • Package mounted radiator

 

Exhaust

  • Exhaust flange outlet

 

Fuel

  • Primary fuel filter with integral water separator
  • Secondary fuel filter
  • Fuel priming pump

 

Generator

  • Matched to the performance and output characteristics of Cat engines
  • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
  • IP23 Protection

 

Power Termination

  • Bus Bar

 

Control Panel

  • EMCP 4 Genset Controller

 

Mounting

  • Rubber vibration isolators

 

Starting/Charging

  • 24 volt starting motor
  • Batteries

 

General

  • Paint – Caterpillar Yellow except rails and radiators gloss black

 

C18 (50 Hz) Optional Equipment

Exhaust

  • Industrial, Residential, Critical Mufflers

 

Generator

  • Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE)
  • Anti-condensation heater
  • Oversize and premium generators

 

Power Termination

  • Circuit breakers, UL listed
  • Circuit breakers, IEC compliant

 

Control Panels

  • EMCP (4.2) (4.3) (4.4)
  • Local & remote annunciator modules
  • Load share module
  • Digital I/O module
  • Remote monitoring software

 

Starting/Charging

  • Battery chargers
  • Oversize batteries
  • Jacket water heater
  • Heavy-duty starting system
  • Charging alternator

 

General

  • The following options are based on regional and product configuration:
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • UL 2200 package
  • EU Certificate of Conformance (CE)
  • CSA Certification
  • EEC Declaration of Conformity
  • Narrow, Wide or Skid Base
  • Sound attenuated, weather protective or high ambient weather protective enclosure
  • Enclosures: sound attenuated, weather protective
  • Single or dual wall integral fuel tanks
  • Single or dual wall sub-base fuel tanks
  • Integral & sub-base UL listed dual wall fuel tanks
  • Automatic transfer switches (ATS)

 